配戴角膜塑形镜对成像质量的影响

姜炳材1 杨积文1,2   

  1. 1 中南大学爱尔眼科学院,长沙 410015;2 沈阳爱尔眼视光医院 110003
  • 收稿日期:2019-02-21 出版日期:2020-03-25 发布日期:2020-03-25
  • 通讯作者: 杨积文,Email:yangjiwen1975@vip.163.com

Effect of orthokeratology on ocular imaging quality

Jiang Bingcai1 Yang Jiwen 1,2   

  1. 1 Aier School of Ophthalmology, Central South University, Changsha 410015, China; 2 Shenyang Aier Eye Hospital, Shenyang 110003, China
  • Received:2019-02-21 Online:2020-03-25 Published:2020-03-25
  • Contact: Yang Jiwen, Email: yangjiwen1975@vip.163.com

摘要: 目的 探讨配戴角膜塑形镜前后角膜、眼内、全眼去除低阶像差的像质参数的变化趋势。设计 前瞻性病例系列。研究对象 选取沈阳爱尔眼视光医院2017年3-6月期间配戴角膜塑形镜者34例(均选右眼)为研究对象,年龄(11.68±1.70)岁,等效球镜(-3.43±1.42)D。方法 应用iTrace视功能分析仪测量5 mm瞳孔直径下戴镜前,戴镜后1周,1、3、6个月的角膜、眼内、全眼的像质参数。像质参数包括在5、10、15、20、25、30周/度(c/d)六个空间频率下的去除低阶像差的调制传递函数值(MTF)和斯特列尔比值(SR)。戴镜前后各像质参数比较采用重复测量方差分析。主要指标 MTF,SR。结果 角膜、眼内、全眼的低中高频MTF值和SR值在戴镜后不同时间点均较戴镜前下降(P均<0.05)。在25 c/d空间频率下,戴镜后1个月角膜MTF值较戴镜后1周下降(P=0.042)。在5 c/d空间频率下,戴镜后1、3个月眼内MTF值较戴镜后1周下降(P=0.027、0.004)。在10、20、25 c/d空间频率下,戴镜后3个月眼内MTF值较戴镜后1周下降(P=0.029、0.013、0.020),戴镜后6个月MTF值较戴镜后3个月提高(P=0.020、0.019、0.042)。在15 c/d空间频率下,戴镜后6个月眼内MTF值较戴镜后3个月提高(P=0.037)。戴镜后1、3个月眼内SR值较戴镜后1周下降(P=0.039、0.015),戴镜后6个月较戴镜后3个月提高(P=0.032)。其余像质参数在戴镜后各时间点两两比较均无统计学差异(P均>0.05)。结论 配戴角膜塑形镜6个月内,去除低阶像差的各像质参数在戴镜后均较戴镜前降低,表明戴镜后去除低阶像差后的眼成像质量下降。角膜高频MTF值,眼内低中高频MTF值和SR值在戴镜后组间存在变化,但戴镜后6个月时这些像质参数恢复到戴镜后1周时水平。(眼科, 2020, 29: 128-132)

关键词: 近视, 角膜塑形镜, 调制传递函数, 斯特列尔比值

Abstract: Objective To investigate the change trend of corneal, internal, ocular imaging quality parameters of subtracted lower order aberration before and after orthokeratology (OK). Design Prospective case series. Participants Thirty-four patients (34 right eyes), mean (11.68±1.70) years old, spherical equivalent diopter (-3.43±1.42) D, who had undergone OK treatment from March to June 2017 in Shenyang Aier Eye Hospital, were chosen for the study and followed up for 6 months. Methods Corneal, internal, ocular imaging quality parameters were measured with the iTrace visual function analyzer under a 5 mm pupil diameter at baseline and after 1 week, 1 month, 3 months, and 6 months of OK lens wearing. Imaging quality parameters include the subtracted lower order aberration modulation transfer function (MTF) at spatial frequencies of 5, 10, 15, 20, 25, 30 cycle/degree (c/d) and strehl ratio (SR). Imaging quality parameters before and after OK were compared with repeated ANOVA. Main Outcome Measures MTF, SR. Results Corneal, internal, ocular low-middle-high spatial frequencies MTF and SR were significantly reduced at different time points after OK in comparison with baseline (all P<0.05). At a spatial frequency of 25 c/d, the corneal MTF decreased after 1 month of OK compared with 1 week after OK (P=0.042). At a spatial frequency of 5 c/d, the internal MTF decreased after 1, 3 months of OK compared with 1 week after OK (P=0.027, 0.004). At spatial frequencies of 10, 20 and 25 c/d, the internal MTF decreased after 3 months of OK compared with 1 week after OK (P=0.029, 0.013, 0.020), and increased after 6 months of OK compared with 3 months after OK(P=0.020, 0.019, 0.042). At a spatial frequency of 15 c/d, the internal MTF increased after 6 months of OK compared with 3 months after OK (P=0.037). The internal SR decreased after 1, 3 months of OK compared with 1 week after OK (P=0.039, 0.015),and increased after 6 months of OK compared with 3 months after OK(P=0.032). There were no statistical differences among the other time points of post-OK (all P>0.05). Conclusion All the subtracted lower order aberration imaging quality parameters decreased after OK, indicating that the subtracted lower order aberration imaging quality declined. Corneal high spatial frequency MTF, internal low-middle-high spatial frequencies MTF and SR changed between the post-OK groups, but the change of 6 months returned to the level of 1 week after OK. (Ophthalmol CHN, 2020,29: 128-132)

Key words: myopia, orthokeratology, modulation transfer function, strehl ratio