浅前房对白内障超声乳化联合人工晶状体植入术后屈光状态的影响

董喆  郝洁  万月  王宁利
  

  1. 100730 首都医科大学附属北京同仁医院 北京同仁眼科中心 眼科学与视觉科学北京市重点实验室
  • 收稿日期:2017-01-23 出版日期:2017-11-25 发布日期:2017-12-02
  • 通讯作者: 王宁利,Email: wningli@vip.163.com E-mail:wningli@vip.163.com

Influence of shallow anterior chamber depth on the refractive status after phacoemulcification combined with intraocular lens implantation

DONG Zhe, HAO Jie, WAN Yue, WANG Ning-li   

  1. Beijing Tongren Eye Center,  Beijing Key Laboratory of Ophthalmology and Visual Sciences, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China
  • Received:2017-01-23 Online:2017-11-25 Published:2017-12-02
  • Contact: WANG Ning-li, Email: Wningli@Vip.163.com E-mail:wningli@vip.163.com

摘要:

目的 探讨中央浅前房对白内障手术后屈光状态的影响。设计 前瞻性病例系列。研究对象 2016年12月至2017年6月在北京同仁医院眼科进行白内障超声乳化联合人工晶状体植入手术且中央前房深度<2.0 mm的患者61例(61眼)为研究组,同期进行手术的中央前房深度≥2.0 mm的患者61例(61眼)为对照组。方法 分别测量浅前房及对照组患者手术眼的眼轴长度、手术前后的前房深度及术后的屈光偏差度数。术后3个月比较两组术眼手术前后的前房深度变化、术后屈光偏差,并对前房深度与眼轴长度进行相关性分析。主要指标 眼轴长度、手术前后前房深度、术后屈光偏差度数。结果 浅前房组术后前房深度变化(1.31±0.14) mm,对照组为(0.79±0.27) mm(P=0.024)。浅前房组及对照组手术眼的前房深度与眼轴长度均为正相关(P=0.001和0.000)。术后3个月浅前房组的目标屈光偏差(0.78±0.16)D,呈远视漂移;对照组目标屈光偏差(-0.37±0.21)D,呈近视漂移。浅前房组较对照组目标屈光偏差的绝对值大(P=0.032)。结论 浅前房白内障患者术后更容易发生远视漂移,在术前进行屈光度数预留设计时要考虑这个可能,作出相应调整。

关键词: 浅前房, 白内障手术, 屈光偏差

Abstract:

Objective To investigate the influence of shallow anterior chamber depth on the refractive status after cataract surgery. Design Prospective case series.  Participants 61 cases (61 eyes) of cataract patients with center anterior chamber depth (CACD) less than 2.0 mm were treated as observed group, and 61 cases (61 eyes) with CACD equal to or more than 2.0 mm as control group. All these cases underwent phaocemulcificatin combined with intraocular lens implantation during Dec. 2016 to Jun. 2017 in Beijing Tongren Eye Center. Methods For all the surgery eyes, the axial length was measured before surgery. CACD and refractive status were measured before and after surgery, and 3 months later separately. The CACD and the refractive status were compared between the two groups 3 months after surgery. Correlation analysis was performed between anterior chamber and axial length. Main Outcome Measures  The axial length, the CACD before and after surgery, and the refractive status. Results The CACD changed 1.31±0.14 mm in the research group, and 0.79±0.27 mm in control group (P=0.024). Both shallow CACD eyes and controlled eyes show positive correlation between CACD and axial length (P=0.001, 0.000). Refractive deviation was 0.78±0.16 D in shallow CACD eyes with hyperopia deviation, and was -0.37±0.21 D in controlled eyes with myopia deviation (P=0.032). Conclusion Shallow CACD eyes showed hyperopia deviation postoperatively. So we should consider the refractive deviation when choosing the IOL diopter for implantation.

Key words: shallow anterior chamber, cataract surgery, refractive deviate